With output voltage capabilities including (110~120)/(220~240V) split phase ,240V single phase the N3H-X12/16US inverter is equipped with a user-friendly interface for effortless monitoring and control. This empowers users to effectively manage their power systems, providing versatile and dependable power for families.
Flexible configuration, plug and play set-up built-in fuse protection.
Includes low-voltage batteries.
Engineered to last with maximum flexibility Suitable for outdoor installation.
Monitor your system remotely via smartphone app or web portal.

|
Technical Data |
N3H-X12US |
N3H-X16US |
|
PV Input Data |
||
| Max. DC Input Power | 18kW | 24kW |
| No. of MPPT Trackers | 4 | |
| MPPT Voltage Range (without battery) | 120 - 500V | |
| MPPT Voltage Range (with battery) | 120 - 430V | |
| MAX.DC Input Voltage | 500V | |
| MAX. Input Current per MPPT | 16A/16A/16A/16A | 20A/20A/20A/20A |
| MAX. Short Current per MPPT | 22A | 25A/25A/25A/25A |
|
Battery Input Data |
||
| Nominal voltage | 48V | |
| MAX. Charging/Discharging Current | 250A/260A | 260A/280A |
| Battery Voltage Range | 40-58V | |
| Battery Type | Lithium / Lead Acid | |
| Charging Controller | 3-Stage with Equalization | |
|
AC Output Data (On-Grid) |
||
| Nominal output power Output to Grid | 12kW | 16kW |
| MAX. Apparent Power Output to Grid | 13.2kVA | 16kVA |
| Nominal AC Voltage (L-N/L1-L2) | (110~120)/(220~240V) split phase ,240V single phase | |
| Nominal AC Frequency | 60Hz (55 to 65Hz) | |
| Nominal AC Current | 50A | 66.7A |
| Max. AC Current | 55A | 73.3A |
| Max. Grid Passthrough Current | 200A | |
| Output THDI | < 3% | |
|
AC Output Data (Back-Up) |
||
| Nominal. Apparent Power | 12kW | 13kW |
| Max. Apparent Power (No PV) | 12kVA | 13.2kVA |
| Max. Apparent Power (With PV) | 13.2kVA | |
| Nominal Output Voltage | 120/240V | |
| Nominal Output Frequency | 60Hz | |
| Output Power Factor | 0.8leading~0.8lagging | |
| Output THDU | < 2% | |
|
Efficiency |
||
| MPPT Efficiency | 99.90% | |
| Europe Efficiency (PV) | 96.20% | |
| Max. PV to Grid Efficiency (PV) | 96.50% | |
| Max. Battery to Load Efficiency | 94.60% | |
| Max. PV to Battery charging Efficiency | 95.80% | |
| Max. GRID to Battery charging Efficiency | 94.50% | |
|
Protection |
||
| Grounding detection | YES | |
| Arc Fault Protection | YES | |
| Island Protection | YES | |
| Insulation Resistor Detection | YES | |
| Residual Current Monitoring Unit | YES | |
| Output Over Current Protection | YES | |
| Back-up Output Short Protection | YES | |
| Output Over Voltage Protection | YES | |
| Output Under Voltage Protection | YES | |
|
General Data |
||
| Operating Temperature Range | -25 ~ +60℃ | |
| Relative Humidity | 0-95% | |
| Operating Altitude | 0~4000m (Derating above 2000m altitude) | |
| Ingress Protection | IP65/NEMA 3R | |
| Weight (with breaker) | 67kg | |
| Dimensions (Width*Height*Depth) | 495mmx900mm x 260mm | |
| Cooling | FAN Cooling | |
| Noise emission | 48dB | |
| Display | Touch panel | |
| Communication With BMS/Meter/EMS | RS485,CAN | |
| Supported communication interface | RS485, 4G (optional),Wi-Fi | |
| Self-consumption | < 25 W | |
| Safety | UL1741,UL1741SA&SB all options, UL1699B, CSA -C22.2 NO.107.1-01,RSD(NEC690.5,11,12) | |
| EMC | FCC Part 15 Class B | |
| Grid connection standards | IEEE 1547, IEEE 2030.5, HECO Rule 14H, | |
| CA Rule 21 PhaseI,II,III,CEC,CSIP,SRD2.0,SGIP,OGPe, | ||
| NOM,California Prob65 | ||
| Object | Description |
| 01 | BAT inpu/BAT output |
| 02 | WIFI |
| 03 | Communication Pot |
| 04 | CTL 2 |
| 05 | CTL 1 |
| 06 | Load 1 |
| 07 | Ground |
| 08 | PV input |
| 09 | PV output |
| 10 | Generator |
| 11 | Grid |
| 12 | Load 2 |