Technical Data |
N3H-X5US |
|||
PV Input Data |
||||
MAX.DC Input Power | 7.5KW |
|||
No.of MPPT Trackers | 4 | |||
MPPT Range | 120 - 430V | |||
MAX.DC Input Voltage | 500V | |||
MAX.Input Current | 14A×4 | |||
Battery Input Data |
||||
Nominal Voltage(Vdc) | 48V |
|||
MAX.Charging/Discharging Current | 120A/120A |
|||
Battery Voltage Range | 40-60V | |||
Battery Type | Lithium and Lead Acid Battery | |||
Charging Strategy for Li-Ion Battery | Self-adaption to BMS | |||
AC Output Data(On-Grid) |
||||
Nominal Output Power Output to Grid | 5KVA |
|||
MAX. Apparent Power Output to Grid | 5.5KVA |
|||
Output Voltage Range | 110-120V/220-240V split phase, 208V(2/3 phase), 230V(1 phase) | |||
Output Frequency | 50/60Hz (45 to 54.9Hz / 55 to 65Hz) | |||
Nominal AC Current Output to Grid | 20.8A |
|||
Max.AC Current Output to Grid | 22.9A |
|||
Output THDI | < 2% | |||
AC Output Data(Back-Up) |
||||
Nominal. Apparent Power Output | 5KVA |
|||
MAX. Apparent Power Output | 5.5KVA |
|||
Nominal Output Voltage L-N/L1-L2 | 120/240V | |||
Nominal Output Frequency | 60Hz | |||
Output Power Factor | 0.8leading …0.8lagging | |||
Output THDU | < 2% | |||
Efficiency |
||||
Europe Efficiency | >=97.8% | |||
MAX. Battery to Load Efficiency | >=97.2% | |||
Protection |
||||
Grounding Detection | YES | |||
Arc Fault Protection | YES | |||
Island Protection | YES | |||
Battery Reverse Polarity | YES | |||
Insulation Resistor Detection | YES | |||
Residual Current Monitoring Unit | YES | |||
Output Over Current Protection | YES | |||
Back-up Output Short Protection | YES | |||
Terminal Temperature Detection | YES | |||
Output Over Voltage Protection | YES | |||
Output Under Voltage Protection | YES | |||
General Data |
||||
Output Conduit | 25.4mm | |||
PV Input Conduit | 25.4mm | |||
BAT Input Conduit | 34.5mm | |||
Operating Temperature Range | -25 ~ +60°C | |||
Relative Humidity | 0-95% | |||
Operating Altitude | 0~4000m | |||
Ingress Protection | IP65/NEMA 3R | |||
Weight | 48kg | |||
Size (Width*Height*Depth) | 450mm x 820mm x 261mm | |||
Cooling | Air Cooling | |||
Noise Emission | <38dB | |||
Display | LCD | |||
Communication With BMS/Meter/EMS | CAN,RS485 | |||
Supported Communication Interface | RS485, WLAN, 4G (optional) | |||
Self-consumption at Night | < 25W | |||
Safety | UL1741SA all options , UL1699B, CSA 22.2 | |||
EMC | FCC Part 15 ClassB | |||
Grid Connection Standards | IEEE 1547, IEEE 2030.5, Hawaii Rule 14H, Rule 21 Phase I,II,III |
Object | Description |
01 | BAT inpu/BAT output |
02 | WIFI |
03 | Communication Pot |
04 | CTL 2 |
05 | CTL 1 |
06 | Load 1 |
07 | Ground |
08 | PV input |
09 | PV output |
10 | Generator |
11 | Grid |
12 | Load 2 |