With output voltage capabilities including 120V/240V (split phase), 208V (2/3 phase), and 230V (single phase), the N3H-X5-US inverter is equipped with a user-friendly interface for effortless monitoring and control. This empowers users to effectively manage their power systems, providing versatile and dependable power for families.
Flexible configuration, plug and play set-up built-in fuse protection.
Includes low-voltage batteries.
Engineered to last with maximum flexibility Suitable for outdoor installation.
Monitor your system remotely via smartphone app or web portal.
Technical Data | N3H-X10US | ||||
PV Input Data | |||||
MAX.DC Input Power | 15KW | ||||
No.of MPPT Trackers | 4 | ||||
MPPT Range | 120 - 430V | ||||
MAX.DC Input Voltage | 500V | ||||
MAX.Input Current | 14A×4 | ||||
Battery Input Data | |||||
Nominal Voltage(Vdc) | 48V | ||||
MAX.Charging/Discharging Current | 190A/210A | ||||
Battery Voltage Range | 40-60V | ||||
Battery Type | Lithium and Lead Acid Battery | ||||
Charging Strategy for Li-Ion Battery | Self-adaption to BMS | ||||
AC Output Data(On-Grid) | |||||
Nominal Output Power Output to Grid | 10KVA | ||||
MAX. Apparent Power Output to Grid | 11KVA | ||||
Output Voltage Range | 110-120V/220-240V split phase, 208V(2/3 phase), 230V(1 phase) | ||||
Output Frequency | 50/60Hz (45 to 54.9Hz / 55 to 65Hz) | ||||
Nominal AC Current Output to Grid | 41.7A | ||||
Max.AC Current Output to Grid | 45.8A | ||||
Output THDI | < 2% | ||||
AC Output Data(Back-Up) | |||||
Nominal. Apparent Power Output | 10KVA | ||||
MAX. Apparent Power Output | 11KVA | ||||
Nominal Output Voltage L-N/L1-L2 | 120/240V | ||||
Nominal Output Frequency | 60Hz | ||||
Output Power Factor | 0.8leading …0.8lagging | ||||
Output THDU | < 2% | ||||
Efficiency | |||||
Europe Efficiency | >=97.8% | ||||
MAX. Battery to Load Efficiency | >=97.2% | ||||
Protection | |||||
Grounding Detection | YES | ||||
Arc Fault Protection | YES | ||||
Island Protection | YES | ||||
Battery Reverse Polarity | YES | ||||
Insulation Resistor Detection | YES | ||||
Residual Current Monitoring Unit | YES | ||||
Output Over Current Protection | YES | ||||
Back-up Output Short Protection | YES | ||||
Terminal Temperature Detection | YES | ||||
Output Over Voltage Protection | YES | ||||
Output Under Voltage Protection | YES | ||||
General Data | |||||
Output Conduit | 25.4mm | ||||
PV Input Conduit | 25.4mm | ||||
BAT Input Conduit | 34.5mm | ||||
Operating Temperature Range | -25 ~ +60°C | ||||
Relative Humidity | 0-95% | ||||
Operating Altitude | 0~4000m | ||||
Ingress Protection | IP65/NEMA 3R | ||||
Weight | 48kg | ||||
Size (Width*Height*Depth) | 450mm x 820mm x 261mm | ||||
Cooling | Air Cooling | ||||
Noise Emission | <38dB | ||||
Display | LCD | ||||
Communication With BMS/Meter/EMS | CAN,RS485 | ||||
Supported Communication Interface | RS485, WLAN, 4G (optional) | ||||
Self-consumption at Night | < 25W | ||||
Safety | UL1741SA all options , UL1699B, CSA 22.2 | ||||
EMC | FCC Part 15 ClassB | ||||
Grid Connection Standards | IEEE 1547, IEEE 2030.5, Hawaii Rule 14H, Rule 21 Phase I,II,III |
Object | Description |
01 | BAT inpu/BAT output |
02 | WIFI |
03 | Communication Pot |
04 | CTL 2 |
05 | CTL 1 |
06 | Load 1 |
07 | Ground |
08 | PV input |
09 | PV output |
10 | Generator |
11 | Grid |
12 | Load 2 |