AIO-H3 energy storage system is an inverter and battery combination, simplifying the installation process. Users do not need to install and connect the inverter and battery separately, they only need to connect the all-in-one unit to the power source. At the same time, it usually provides user-friendly operation interfaces, allowing users to easily monitor and manage the system.
Lithium iron phosphate batteries adopt stable and safe modular, battery pack and system designs with triple protection.
Supports controlling the adjustable power (DI/DO) of each phase of the diesel generator.
Modular design with plug-and-play functionality for mobile application monitoring.
It can accommodate 200% of ultra-large photovoltaic power generation systems for grid-connected and off-grid parallel operation.
Hybrid inverters combined with energy storage systems provide power during main grid outages and supply power to the grid when the grid is operating normally.
The all-in-one design allows for higher system efficiency. The integration between the inverter and the battery optimizes the efficiency of energy transmission and conversion and reduces energy loss. This enables the system to provide a stable power supply with greater efficiency during use.
Model | AIO-H3-8.0 |
Hybrid Inverter Model | N3H-A8.0 |
PV String Input | |
Max. Continious PV Input Power | 16000 W |
Max. DC Voltage | 1100 V |
Nominal Voltage | 720 V |
MPPT Voltage Range | 140- 1000 V |
MPPT Voltage Range (Full Load) | 380~850 V |
Number of MPPT | 2 |
Strings Per MPPT | 1 |
Max. Input Current | 2* 15 A |
Max. Short-circuit Current | 2*20 A |
AC Output (Grid) | |
Nominal AC Output Power | 8KW |
Max. AC Apparent Power | 8800 VA |
Rated input/output voltage | 3/N/PE, 230/400 V |
AC Grid Frequency Range | 50/60 Hz ± 5Hz |
Nominal Output Current | 11.6 A |
Max. Output Current | 12.8 A |
Power Factor (cosCD) | 0.8 Leading-0.8 Lagging |
Battery Input | |
Battery Type | LFP (LiFeP04) |
Nominal Battery Voltage | 51.2 V |
Charging Voltage Range | 44-58 V |
Max. Charging Current | 160 A |
Max. Discharging Current | 160 A |
Battery Capacity | 200/400/600/800 Ah |
AC Output (Backup) | |
Nominal AC Output Power | 7360 W |
Max. AC Output Power | 8000 VA |
Nominal Output Current | 10.7 A |
Max. Output Current | 11.6 A |
Nominal Output Voltage | 3/N/PE, 230/400 V |
Nominal Output Frequency | 50/60 HZ |
Efficiency | |
Max. PV Efficiency | 97.60% |
Euro. PV Efficiency | 97.00% |
Anti-islanding Protection | Yes |
Output Over Current Protection | Yes |
DC Reverse Polarity Protection | Yes |
String Fault Detection | Yes |
DC/AC Surge Protection | DC Type II; AC Type III |
Insulation Detection | Yes |
AC Short Circuit Protection | Yes |