ARM版本:B00D04
1、修复彩屏通信口数据发送不完整的问题
2、铅酸回差电压默认值改为4V
3、0x3444电网能力和0x348C电网充电功率会根据机型给默认值
DSP版本:B00D24
1、支持208v伏系统并联，支持208v相序反设置
2、增加dsp boot版本上传
3、铅酸使用0x3476做电池低压告警点，0x3477做回差设置
4、解决250v mpp曲线追踪不好的问题

ARM Version: B00D04
1. Fix the issue of incomplete data transmission on the color screen communication port.
2. Change the default value of the lead-acid return difference voltage to 4V.
3. The default values of 0x3444 grid capability and 0x348C grid charging power will be based on the model.

DSP Version: B00D24
1. Support parallel connection of 208V systems, and support the setting of 208V phase sequence reversal.
2. Add DSP boot version upload.
3. Use 0x3476 for the lead-acid battery low voltage alarm point, and 0x3477 for the return difference setting.
4. Solve the issue of poor tracking of the 250V MPP curve.